Signal Conditioners and Isolators

Results: 727
Stocking Options
Environmental Options
Media
Exclude
727Results

Showing
of 727
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Type
Input Range (Current, Voltage)
Input Range (Additional)
Output Type
Output Range
Isolation
Features
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
ADAM-3014-AE
ISOLATED DC I/O MODULE
Advantech Corporation
53
In Stock
23
Factory
Active
Box
Active
Isolation Amplifier
Current, Voltage
±20mA, ±10V (Configurable)
-
Current, Voltage
0 ~ 20mA, ±10V
1000V
-
24VDC
DIN Rail
Screw Terminal
-10°C ~ 70°C
2517450000
PICOPAK-CI-CO-LP-S
Weidmüller
56
In Stock
161
Factory
Active
-
Bulk
Active
Passive Isolator
Current
4 ~ 20mA
-
Current
4 ~ 20mA
-
-
Loop Powered
DIN Rail
Screw Terminal
-40°C ~ 70°C
2901994
SINGLE-CHANNEL INPUT LOOP-POWERE
Phoenix Contact
47
In Stock
259
Factory
Active
Bulk
Active
Isolation Amplifier
Current
0 ~ 20mA
-
Current
0 ~ 20mA
3000V (Test)
-
Loop Powered
DIN Rail
Screw Terminal
-40°C ~ 70°C
7760054122
SIGNAL DISTRIBUTOR SCREW CONN
Weidmüller
63
In Stock
101
Factory
Active
Bulk
Active
Signal Conditioner
Current
4 ~ 20mA
-
Current
4 ~ 20mA
300V (Working), 2000V (Test)
-
Loop Powered
DIN Rail
Screw Terminal
-20°C ~ 60°C
2902002
MINI MCR-2-I4-U
Phoenix Contact
45
In Stock
Active
Bulk
Active
Signal Conditioner
Current
4 ~ 20mA
-
Voltage
0 ~ 10V
-
-
24VDC
DIN Rail
Screw Terminal
-40°C ~ 70°C
45
In Stock
265
Factory
Active
Bulk
Active
Isolation Amplifier
Current
0 ~ 20mA
-
Current
0 ~ 20mA
-
-
24VDC
DIN Rail
Screw Terminal
-40°C ~ 70°C
2902061
OUTPUT LOOP-POWERED 2-WAY ISOLAT
Phoenix Contact
78
In Stock
965
Factory
Active
Bulk
Active
Signal Conditioner
Current
4 ~ 20mA, ±20V (Configurable)
-
Current
4 ~ 20mA (Configurable)
3000V (Test)
-
Loop Powered
DIN Rail
-
-25°C ~ 65°C
2902063
OUTPUT LOOP-POWERED 2-WAY ISOLAT
Phoenix Contact
26
In Stock
169
Factory
Active
Bulk
Active
Signal Conditioner
Current, Voltage
0 ~ 40mA, ±30V (Configurable)
-
Current
4 ~ 20mA
3000V (Test)
-
Loop Powered
DIN Rail
Spring Terminal
-40°C ~ 70°C
2902019
MINI MCR-2-U-UI
Phoenix Contact
48
In Stock
192
Factory
Active
Bulk
Active
Signal Conditioner
Voltage
0 ~ 10V
-
Voltage
±10V
3000V
-
24V
DIN Rail
Screw Terminal
-40°C ~ 70°C
11760,1375
SIGNAL CONVERTER/DISCONNECTOR
Weidmüller
37
In Stock
6
Factory
Active
Bulk
Active
Signal Conditioner
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
300V (Working), 2500V (Test)
-
24VDC
DIN Rail
Screw Terminal
-25°C ~ 70°C
DR-I3P
ISOLATED SIGNAL TRANSMITTER, AC/
Omega
40
In Stock
Active
-
Bulk
Active
Signal Conditioner
Current, Voltage, Resistance, Temperature
4 ~ 20mA
-
Current, Voltage
4 ~ 20mA, 0 ~ 10V
2300V
Excitation Supply
18 ~ 265VAC/DC
DIN Rail
Screw Terminal
0°C ~ 50°C
29020xx
MINI MCR-2-UI-UI
Phoenix Contact
297
In Stock
541
Factory
Active
Bulk
Active
Signal Conditioner
Current, Voltage
±20mA, ±30V (Configurable)
-
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
-
24VDC
DIN Rail
Screw Terminal
-40°C ~ 70°C
26
In Stock
35
Factory
Active
Bulk
Active
Signal Conditioner
Current
0 ~ 20mA
-
Current
0 ~ 20mA
2000V
-
20 ~ 30VDC
DIN Rail
Screw Terminal
-20°C ~ 60°C
2810780
3-WAY ISOLATING AMP 4-20MA
Phoenix Contact
40
In Stock
Active
Bulk
Active
Signal Conditioner
Voltage
±3V (Configurable)
-
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
1500V (Test)
-
24VDC
DIN Rail
Screw Terminal
-20°C ~ 65°C
2864406
MCR 3-WAY ISOLATING AMPLIFIER
Phoenix Contact
28
In Stock
120
Factory
Active
Bulk
Active
Isolation Amplifier
Current
0 ~ 20mA
-
Current
0 ~ 20mA
1500V (Test)
-
24VDC
DIN Rail
Screw Terminal
-20°C ~ 65°C
2905026
UNIVERSALLY CONFIGURABLE 4-WAY S
Phoenix Contact
162
In Stock
917
Factory
Active
Bulk
Active
Signal Conditioner
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
3000V (Test)
-
24VDC
DIN Rail
Screw Terminal
-40°C ~ 70°C
2905028
UNIVERSALLY CONFIGURABLE 4-WAY S
Phoenix Contact
89
In Stock
453
Factory
Active
Bulk
Active
Signal Conditioner
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
3000V (Test)
-
24VDC
DIN Rail
Spring Terminal
-40°C ~ 70°C
2864176
4-WAY SIGNAL DUPLICATOR
Phoenix Contact
121
In Stock
351
Factory
Active
Bulk
Active
Signal Conditioner Multiplier
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
Current
0 ~ 20mA (Configurable)
1500V (Test)
-
24VDC
DIN Rail
Screw Terminal
-20°C ~ 60°C
857-400
ISOLATION AMPLIFIER; CURRENT AND
WAGO Corporation
29
In Stock
Active
-
Bulk
Active
Isolation Amplifier
Current, Voltage
-
-
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V
-
24VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
2811446
ISOLATED AMP DIN RAIL
Phoenix Contact
37
In Stock
210
Factory
Active
Bulk
Active
Signal Conditioner
Current, Voltage
±100mA, ±100V (Configurable)
-
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V (Test)
-
12 ~ 24VDC
DIN Rail
Spring Terminal
-20°C ~ 70°C
2902014
MINI MCR-2-RPSS-I-I
Phoenix Contact
44
In Stock
80
Factory
Active
Bulk
Active
Isolation Amplifier
Current
0 ~ 20mA
-
Current
0 ~ 20mA
-
-
24VDC
DIN Rail
Screw Terminal
-40°C ~ 70°C
2456160000
SIGNAL CONVERTER/INSULATOR SAFE-
Weidmüller
66
Marketplace
Active
Bulk
Active
Signal Conditioner
Current
4 ~ 20mA
-
Current
4 ~ 20mA
300V (Working), 2600V (Test)
-
19.2 ~ 31.2VDC
DIN Rail
Screw Terminal
-20°C ~ 60°C
106
Marketplace
Obsolete
Bulk
Obsolete
Signal Conditioner
Current
4 ~ 20mA
-
Voltage
0 ~ 10V
300V (Working), 2000V (Test)
-
24VDC
DIN Rail
Screw Terminal
0°C ~ 70°C
2456110000
SIGNAL CONVERTER/INSULATOR SAFE-
Weidmüller
95
Marketplace
Active
Bulk
Active
Signal Conditioner
-
-
-
-
-
300V (Working), 2600V (Test)
-
19.2 ~ 31.2VDC
DIN Rail
Screw Terminal
-20°C ~ 60°C
2044840000
CURRENT-MEASURING TRANSDUCER INP
Weidmüller
69
Marketplace
Active
Bulk
Active
Signal Conditioner
Current
0 ~ 10A (Configurable)
-
Current, Voltage
±20mA, ±10V (Configurable)
300V (Working), 4000V (Test)
-
24VDC
DIN Rail
Screw Terminal
-
Showing
of 727

Signal Conditioners and Isolators


Signal conditioners are used to convert signals to a different level or type often for sensor measurements. Isolators are devices that separate or isolate one circuit from another in regard to power. Types available include isolation amplifiers, passive isolators, signal conditioners, and more. These are defined by various parameters including input type, output type, isolation voltage, extra features and more.